高原进排气模拟系统
-
Technical Data and Requirements
Max. Altitude
5.500m above sea level (practically)
Min. Altitude
800m under sea level
Pressure Regulation Accuracy
+/- 1 mbar (approx. 10m)
Altitude System/ projects experience
Import and more than 5 projects experience
AHU (Air Conditional Unit)
Local / China
Pipe and Install and Pressure Container
Provide Chinese safety qualification / China
Pressure Stability
+/- 5 mbar (approx. 50m)
Altitude Variation Speed
250 m/s
Temperature Range
From 10°C to +60°C (practically)
Temperature Stability
+/- 1°C
Max. Engine Intake Air Flow
2.800 kg/h (practically)
Interface
Drive With Horiba
Service
12 months warranty
满足中国GB17691-2005 and GB17691-2018规定的试验室大气因子的要求(试验室大气因子0.96≤Fa≤1.06)
ECE R49 <Uniform provisions concerning the measures to be taken against the emission of gaseous and particulate pollutants from compression-ignition engines and positive ignition engines for use in vehicles>
能够模拟0-5500m海拔的发动机进排气条件;满足中国GB17691-2005和GB17691-2018规定的试验室大气因子的要求(试验室大气因子0.96≤Fa≤1.06)。
进气量:≥3200kg/h。
进气空气调温度测量范围-10—70℃;进气空气温度工作温度范围0—50℃。
温度设置及控制范围: 20~40℃;温度控制精度: ±1℃(发动机进气口温度)。
进气压力调节及显示范围: 54~105kPa;进气压力调节精度: ±5 mbar。
进气湿度测量范围: 0-100%;湿度测量精度不低于3%。
进气湿度调节范围:+35-70%;进气湿度调节精度:<±3%R.H。
动态进气空调响应时间:≤3s。
进气空气温度,湿度,压力传感器应应装在靠近发动机进气入口处。
发动机稳态工况下,进气空气调温度稳定并达到温度控制精度内的时间不得大于60秒。
具体根据发动机功率大小搭配合适的流量;或者根据模拟的海拔高度满足对应的进气量。
设备运行时噪音应小于100分贝。
冷冻水或冷却水管入口处应自带过滤器。
安装需要方便,使用快速接头连接到发动机入口和出口。
-
-
通过改变风机的速度来控制总流量,从而使其适应被测发动机的类型。当被测发动机较小时,可减少系统中的流量, 从而减少所用功率,达到系统节能的要求。
EACS simulates different altitude conditions when testing the engine. 发动机测试时,使用EACS可模拟不同的海拔条件
It can be installed in standard engine test cells or chassis-dyno. 该系统可安装应用于发动机试验室或整车底盘测功台架
Its extremely fast response allows to perform any kind of test including RDE.
该系统的极端高速响应使您可以用之运行任何试验,包括RDE( Real Driving Emissions)