EME410 Engine coolant conditioning system 冷却液温度控制系统
-
Feature
EME410 Engine coolant conditioning system EME410冷却液温度控制系统
The coolant conditioning system EME410 is used for bringing the engine coolant to a free definable temperature and to keep it within tight limits.用于对发动机温度的控制,以保证发动机的主要零部件在最佳温度下工作。
The structure include heat exchanger, electric control valve for water temperature, electric valve for makeup water and ball valve, expand water tank with discharge pressure cover on the top , level sensor and pressure guage. It is mounted system of the antifreeze (and anti rust). 本系统包括热交换器、水温控电动调节阀、补水电磁阀和相应的手动球阀,系统顶部膨胀水箱装有卸压水箱盖、液位传感器和压力显示仪表。有些特别装备了防冻防锈液补液和回液系统。
There are the alarm and stop for the exceed temperature and water lack. Temperature control is adjusted by PID, directly control the water temperature, the outer water temperature set can be changed by the control computer. 系统具有超温、缺水报警停机等安全功能。采用西门子电动比例调节阀门,可以直接实现出水温度控制,可以由试验台计算机改变出水温度设定。
EME冷却液温度控制系统 EME411 EME412 EME413 EME414 EME415 EME416 EME417 EME418 适用发动机功率 160kw 160kw 260kw 260kw 450kw 450kw 600kw 600kw 加热功率 无 12kw 无 12kw 无 12kw 无 12kw 温度控制范围 40-120℃ 40-120℃ 40-120℃ 40-120℃ 40-120℃ 40-120℃ 40-120℃ 40-120℃ 控制精度 ±1℃ ±1℃ ±1℃ ±1℃ ±1℃ ±1℃ ±1℃ ±1℃ (发动机端)冷却液流量m³/h 8 8 16 18 20 25 32 32 系统耐压测试 0.6MPa 0.6MPa 0.6MPa 0.6MPa 0.6MPa 0.6MPa 0.6MPa 0.6MPa 系统耐温测试 150℃ 150℃ 150℃ 150℃ 150℃ 150℃ 150℃ 150℃ 发动机冷却液管接口(通径) DN32 DN32 DN40 DN40 DN50 DN50 提供发动机端尺寸 提供发动机端尺寸 外循环冷却水管接口(通径) DN32 DN32 DN40 DN40 DN50 DN50 提供发动机端尺寸 提供发动机端尺寸 补液管路(系统具备自动补液功能) DN20 DN20 DN20 DN20 DN20 DN20 DN20 DN20 用户提供保障 电源(用户提供):380VAC ±10%; 16A 冷却水压力(用户提供):0.15~0.3 MPa (回水无背压) 冷却水温度(用户提供) ≤32℃ 流量与发动机内循环基本等同 Technical
Technical data
EME412
Nominal Performance of Combustion Engine
160KW
Engine Circuit
Coolant connection engine
DN32
Nominal flow[m3/h],approx.
8 m3/h
Adjustable coolant temperature[℃] (outlet CoolCon)
40-110℃
Maximum output temperature tout,max [°C]
110℃
Setting accuracy,
±1℃
Max. permissible pressure
0.6Mpa
Nominal cooling capacity PT
120KW
Nominal heating power (optional)
12KW
Cooling Water Supply
Cooling Water Supply
DN32
Feed temperature[℃]
32℃ lower than requested coolant temperature
Cooling water pressure
0.2~0.3MPa
Cooling water flow
8 m3 /h
Nominal Feedback pressure dPmin [kPa] (最优)
0
Nominal pressure difference dPmin [kPa]
300
Mechanical Data
Dimensions(wXhXd),wall mounted
800X1800 X450
Weight
200KG
Color
RAL7035
系统采用西门子MXG461电磁调节阀须定位快(<2s)、灵敏度高(>1:1000)
Technical data
EME414
Nominal Performance of Combustion Engine
260KW
Engine Circuit
Coolant connection engine
DN40
Nominal flow[m3/h],approx.
18 m3/h
Adjustable coolant temperature[℃] (outlet CoolCon)
40-110℃
Maximum output temperature tout,max [°C]
110℃
Setting accuracy,
±1℃
Max. permissible pressure
0.6Mpa
Nominal cooling capacity PT
200KW
Nominal heating power (optional)
12KW
Cooling Water Supply
Cooling Water Supply
DN40
Feed temperature[℃]
32℃ lower than requested coolant temperature
Cooling water pressure
0.2~0.3MPa
Cooling water flow
20 m3 /h
Nominal Feedback pressure dPmin [kPa](最优)
0
Nominal pressure difference dPmin [kPa]
300
Mechanical Data
Dimensions(wXhXd),wall mounted
800X1800 X450
Weight
260KG
Color
RAL7035
系统采用西门子MXG461电磁调节阀须定位快(<2s)、灵敏度高(>1:1000)
Technical data
EME416
Nominal Performance of Combustion Engine
450KW
Engine Circuit
Coolant connection engine
DN50
Nominal flow[m3/h],approx.
25 m3/h
Adjustable coolant temperature[℃] (outlet CoolCon)
40-110℃
Maximum output temperature tout,max [°C]
110℃
Setting accuracy,
±1℃
Max. permissible pressure
0.6Mpa
Nominal cooling capacity PT
400KW
Nominal heating power (optional)
12KW
Cooling Water Supply
Cooling Water Supply
DN50
Feed temperature[℃]
32℃ lower than requested coolant temperature
Cooling water pressure
0.2~0.3MPa
Cooling water flow
25 m3 /h
Nominal Feedback pressure dPmin [kPa] (最优)
0
Nominal pressure difference dPmin [kPa]
300
Mechanical Data
Dimensions(wXhXd),wall mounted
1150X1900 X850
Weight
300KG
Color
RAL7035
系统采用西门子MXG461电磁调节阀须定位快(<2s)、灵敏度高(>1:1000)
Technical data
EME418
Nominal Performance of Combustion Engine
600KW
Engine Circuit
Coolant connection engine
DN65
Nominal flow[m3/h],approx.
30 m3/h
Adjustable coolant temperature[℃] (outlet CoolCon)
40-110℃
Maximum output temperature tout,max [°C]
110℃
Setting accuracy,
±1℃
Max. permissible pressure
0.6Mpa
Nominal cooling capacity PT
400KW
Nominal heating power (optional)
14KW
Cooling Water Supply
Cooling Water Supply
DN65
Feed temperature[℃]
32℃ lower than requested coolant temperature
Cooling water pressure
0.2~0.3MPa
Cooling water flow
30 m3 /h
Nominal Feedback pressure dPmin [kPa] (最优)
0
Nominal pressure difference dPmin [kPa]
300
Mechanical Data
Dimensions(wXhXd),wall mounted
1150X1900 X850
Weight
400KG
Color
RAL7035
系统采用西门子MXG461电磁调节阀须定位快(<2s)、灵敏度高(>1:1000)
Applications
Scope of Supply
Quantity
The main part of coolant conditioning system冷却液温度控制系统主体
1
Cable15M电缆线15M
1
Signal wire15M 信号线15M
1
Delivery ,insurance 运输,保险
1
Scope of supply, survey report, user manual
发货清单、出厂检验报告、安装及使用说明书
1
On request the cooling capacities can be varied by individual dimensioning of the heat exchanger.
Interface
EME410
Power
380VAC±10%;32A
Fluid infusion supply补液管路
DN20
STARS interface STAR接口
WAGO-CANOPEN
WAGO包含:Alarm on level 液位报警传输
Digital 开/关
WAGO包含:Circuit water pump power supply control循环水泵电源控制
Digital 开/关
WAGO包含:Heater power supply control
加热器电源控制
Digital 开/关
WAGO包含:阀门PID控制
模拟量输出
配线长度
20
Cooling water with pressure and flow rate steady on outlet provide by consumer. For example, pressure on outlet undulate or 7℃ refrigeration water regard as cooling water on outlet; There must have special instructions when reserving the unit.
用户提供压力流量稳定的外循环水路,如外循环水压波动过大或应用7度制冷水做外循环水;须在设备订购时特殊说明。
Option可选件
品牌
FLOW METER水流量计
YOKOGOWA
自动抽补水小车
EME
变频控制器
EMERSON
EME条件控制集中控制器(水油中冷集中控制)
EME
外循环水稳压、污水隔离装置
EME
快速接头板
STAUBLI
如需可选件,请于订购前特殊说明;027-84213182武汉东测科技有限责任公司
-
-